True RMS: |
LCD display | 6000 |
---|---|
Range selection | automatic/manual |
DC voltage | 1000 V ± 0,1% |
AC voltage | 1000 V ± 0,5% |
DC current | 10A ± 0,4% |
AC current | 10A ± 1,2% |
Resistance | 20 MΩ ± 0,4% |
Conductance | 60 nS ± 1,0% |
Capacitance | 10 mF ± 1,0% |
Frequency | 200kHz ± 0,005% |
Continuity test | yes |
Diode test | yes |
Auto power off | yes |
Data hold | yes |
Back light | yes |
Battery indicator | yes |
Dimensions | 200 x 95 x 48 mm |
Power | 9V battery (6F22) |
Guarantee | Unlimited |
Manufacturer | Fluke |
LCD display | 19,999 |
---|---|
Range selection | automatic/manual |
DC voltage | 1000 V ± 0,1% |
AC voltage | 1000 V ± 0,5% |
DC current | 10A ± 0,4% |
AC current | 10A ± 1,2% |
Resistance | 20 MΩ ± 0,4% |
Conductance | 60 nS ± 1,0% |
Capacitance | 10 mF ± 1,0% |
Frequency | 200kHz ± 0,005% |
Temperature | -200 ÷ 1090 °C ± 1,0% |
Continuity test | yes |
Relative measurement | yes |
Diode test | yes |
Auto power off | yes |
Data hold | yes |
True RMS | yes |
Back light | yes |
Battery indicator | yes |
Dimensions | 200 x 95 x 48 mm |
Power | 9V battery (6F22) |
Guarantee | Unlimited |
Manufacturer | Fluke |
Range selection | automatic |
---|---|
AC voltage | 4÷600 V ± 1% |
DC voltage | 4÷1000 V ± 1% |
AC current | 40÷1400 A ± 1,5% |
DC current | 40÷2000 A ± 1,5% |
Resistance | 400 Ω ÷ 400 kΩ ± 1,5% |
Frequency | 5Hz÷1kHz |
True RMS | yes |
Sound signal | yes |
Data hold | yes |
Highlighted LCD | yes |
Battery indicator | yes |
Protection | yes |
Max. clamp set | 58 mm |
Dimensions | 300 x 98 x 52 mm |
Power | 6x AA battery |
Weight | 814g |
Manufacturer | Fluke |
Range selection | automatic |
---|---|
AC voltage | 600 V ± 1% |
DC voltage | 600 V ± 1% |
AC current | 600 A ± 1% |
DC current | 200 µA ± 1% |
Resistance |
up to 600 Ω ± 1.5%, up to 6000 Ω ± 1.5% |
Frequency | 5÷400 Hz ± 0.5% |
Temperature | -10° - 400°C ± 1% |
Capacitance | 1 - 1000 µF ± 1.9% |
Crest factor |
2.4 @ 500 A, 2.0 @ 600 A |
True RMS | yes |
Sound signal | yes |
Data hold | yes |
Highlighted LCD | yes |
Battery indicator | yes |
Protection | yes |
Max. clamp set | 30 mm |
Dimensions | 38 x 79 x 41 mm |
Power | 2x AA battery |
Weight | 312g |
Manufacturer | Fluke |
Multimeter | |
---|---|
Max. LCD display | 5999 |
Range selection | automatic |
Insulation class | CAT II 1000V |
DC voltage | 600m/6/60/600/1000 V ± 0,5% |
AC voltage | 600m/6/60/600/1000 V ± 0,8% |
DC current | 600/1000 A ± 2,5% |
AC current | 600/1000 A ± 1,8% |
Resistance |
600/6k/60k/600k ± 0,8%, 6M/60M Ω ± 1,2% |
Frequency range | 60/600/6k/60k/600k/6M/60M Hz ± 0,3% |
Capacitance | 60n/600n/6µ/60µ/600µ/6m/60m F ± 4% |
Temperature | -40÷500°C ± 1,0% |
Continuity test | yes |
Sampling time | 300ms |
Diode test | yes |
Max. diameter for conductor | Ø40 mm |
Power | 3x 1,5V AAA battery |
Manufacturer | Mastech |
Infrared thermometer | |
Temperature | -20÷350 °C ± 2,5% |
Field of view | 6÷1 |
Emmisivity | 0,95 |
Sampling time | 300ms |
Power | 2xLR44 |
Multimeter | |
---|---|
Range selection | automatic/manual |
DC voltage | 1000 V ± 0,1% |
AC voltage | 1000 V ± 0,5% |
DC current | 30mA ± 0,05% |
AC current | 30mA ± 0,05% |
Resistance | 40 MΩ ± 0,2% |
Frequency | 200kHz ± 0,005% |
Continuity test | yes |
Relative measurement | yes |
Diode test | yes |
True RMS | yes |
Calibrator | |
Current source | 0-20 mA and 4-24 mA ±0,05% of range |
Loop supply | 24V |
Step | auto / manual |
Other | |
PC Interface | yes (infrared) |
Dimensions | 203 x 100 x 50 mm |
Power | 4 x 1,5V AA battery |
Weight | 0,6kg |
Guarantee | 3 lata |
Manufacturer | Fluke |