Output
|
24V
|
1A
|
0÷1A
|
24W
|
150mVp-p
|
21.6÷26.4V
|
±1.0%
|
±1.0%
|
±1.0%
|
500ms & 30ms/230VAC at full load, 1000ms & 30ms/115VAC at full load
|
50ms/230VAC at full load, 20ms/115VAC at full load
|
Input
|
85÷264VAC, 120÷370VDC
|
47÷63Hz
|
84%
|
0.55A/115VAC, 0.35A/230VAC
|
20A/115VAC cold start, 40A/230VAC cold start
|
<1mA/240VAC
|
Protection
|
105%÷160% rated output power, protection type - constant current limiting - recovers automatically after fault condition is removed
|
27.6÷32.4V, protection type - shut down o/p voltage & re-power on to recover
|
Function
|
18÷27V/20mA
|
Environment
|
-20°C ÷ 70°C
|
20÷90% RH non-condensing
|
-40°C ÷ 85°C
|
10÷95% RH
|
±0.03%/°C (0÷50°C)
|
10÷500Hz, 2G 10min./1cycle, 60min. each along X Y Z axes
|
compliance to IEC60068-2-6
|
Safety & EMC
|
UL508, TUV EN60950-1, NEC class 2 / LPS
|
I/P-O/P 3kVAC, I/P-FG 1.5kVAC, O/P-FG 0.5kVAC
|
I/P-O/P 100MΩ/500VDC, I/P-FG 100MΩ/500VDC, O/P-FG 100MΩ/500VDC
|
EN55011, EN55022 (CISPR22), EN61204-3 Class B
|
EN61000-3-2, EN61000-3-3
|
EN61000-4-2/3/4/5/6/8/11, ENV50204, EN55024, EN61000-6-1, EN61204-3, light industry level criteria A
|
Others
|
min. 236900h MIL-HDBK-217F (25°C)
|
22.5mm x 90mm x 100mm
|
0.19kg
|
3 years |